Main Brands:

Bently, Triconex, Woodward, Foxboro,Reliance, ABB, Allen-Bradley, Motorola, GE, Yaskawa, Bosch Rexroth, ACSO, YOKOGAWA, NI, ICS Triplex, Kollmorgen, Mitsubishi, MOOG, Emerson, B&R, SST, ALSTOM, EPRO, HIMA, HONEYWELL prosoft, AMAT.

Wei Xiu zhu
WhatsApp:+852 5796 0986
Wechat:13395077993
Zhejiang Yiwu Beixun Automation Technology Co., Ltd
China (Zhejiang) Pilot Free Trade Zone, No. 2 Chunpai Road, Beiyuan Street, Yiwu City, Jinhua City, 7F 7059
website:www.bxplc2.com
Email: 3076784238@qq.com

 

HIMA F3330 Product Specifications

Product Code: F3330
Manufacturer: HIMA
Description: 8-Channel Digital Output Module
Product Series: HIMatrix F Series
Safety Certification: SIL 3 according to IEC 61508
Number of Outputs: 8 channels
Output Current: 500mA per channel (resistive load), 1A (inductive load)
Power Supply: 24V DC
Power Consumption: 5V DC: 110mA, 24V DC: 180mA
Dimensions (W×H×D): 70mm × 125mm × 90mm
Weight: Approximately 0.6kg
Operating Temperature: -25°C to +70°C
Storage Temperature: -40°C to +85°C
Humidity Range: 5% to 95% non-condensing
Certifications: CE, cULus, ATEX, IECEx
HIMA F3330  8-Channel Digital Output Module

Related Series:

HIMA F3330

HIMA F3236

HIMA F3322

HIMA K9203

HIMA K9202

Key Features

  • 8-channel digital output module designed for safety-related applications
  • Integrated safety shutdown functionality
  • Safe isolation (Ex) for hazardous area applications
  • Line short circuit monitoring (LS) for enhanced safety
  • Line break monitoring (LB) for fault detection
  • Suitable for both resistive and inductive loads up to 500mA (12W)
  • Supports lamp connections up to 4W
  • No output voltage when L-supply is disconnected
  • High reliability and robustness for industrial environments
  • Short circuit proof outputs with current limiting
  • Fast response time with maximum 1ms polling time per channel

Technical Specifications

Output Type Digital outputs, short circuit protected
Load Capacity Resistive: up to 500mA (12W), Inductive: up to 1A
Internal Voltage Drop Maximum 2V at 500mA load
Admissible Line Resistance Maximum 11 ohms (input + output)
Under Voltage Trip Point ≤ 16V
Short Circuit Current Operation Point 0.75 to 1.5A
Output Leakage Current Maximum 350μA
Output Reset Voltage Maximum 1.5V
Test Signal Duration Maximum 200μs
Space Requirement 4 TE (Terminal Equipment units)
Communication Interfaces Safe Ethernet, Modbus TCP
Requirement Class AK 1 … 6

Applications

  • Chemical and petrochemical industries
  • Oil and gas production and refining
  • Power generation facilities
  • Pharmaceutical manufacturing
  • Food and beverage processing
  • Manufacturing automation
  • Transportation systems
  • Water and wastewater treatment
  • Hazardous area applications requiring Ex certification
  • Safety instrumented systems (SIS)
  • Emergency shutdown systems (ESD)