The Vibrometer MPC4 200-510-SSS-1HH is a high-performance machinery protection card designed for the VM600 rack-based monitoring system. This advanced card provides continuous online monitoring and protection for critical rotating machinery in industrial environments. It utilizes state-of-the-art DSP (Digital Signal Processing) technology to deliver real-time measurement and analysis of vibration and other mechanical parameters.
Key Features
- 4 programmable dynamic signal inputs for vibration, displacement, and other measurements
- 2 programmable tachometer/speed inputs for rotational speed monitoring
- Advanced DSP technology for real-time measurement and monitoring
- Programmable wideband and narrowband filters
- Order tracking with simultaneous amplitude and phase monitoring
- Programmable alarm, danger setpoints, and OK values
- Adaptive warning and danger levels based on machine speed
- Front panel BNC connectors for easy raw signal analysis
- 7 front panel LEDs for status and alarm indication
- Integrated power supply for various sensor types
- Hot-swappable design for easy maintenance

Technical Specifications
General Specifications
| Parameter | Value |
|---|---|
| Model Number | 200-510-SSS-1HH |
| Card Type | Standard Version (1 = Standard) |
| Dimensions (W x H x D) | 200 mm x 150 mm x 30 mm |
| Weight | Approximately 1.5 kg |
| Protection Rating | IP20 |
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 0 to 95% non-condensing |
| Power Supply | +5 V DC ±5% and ±12 V DC |
| Power Consumption | 12.5 W (plus 1 W per sensor) |
Dynamic Signal Inputs
| Parameter | Value |
|---|---|
| Number of Inputs | 4 per MPC4 card |
| DC Range | 0 to +20 V or 0 to -20 V |
| AC Range | ±10 V (maximum) |
| Common Mode Voltage Range | -50 to +50 V |
| CMRR | >60 dB at 50 Hz |
| Crosstalk | -72 dB |
| Input Impedance | 200 kΩ |
| Current Input Range (DC) | 0 to 25 mA |
| Current Input Range (AC) | ±8 mA (maximum) |
| Analog AC Frequency Range (not integrated) | 0.1 Hz to 10 kHz |
| Analog AC Frequency Range (with integration) | 2.5 Hz to 10 kHz |
Processing Capabilities
| Parameter | Value |
|---|---|
| Filtering Options | High-pass, low-pass, or band-pass |
| LP/HP Ratio in Bandwidth | 500 (maximum) |
| Ripple | ±0.3 dB |
| Slope | 6 to 60 dB/octave (software configurable) |
| Out-of-Band Attenuation | >50 dB |
| Amplitude Accuracy | ±1% of full scale |
| Linear Error | <±1% |
| Equivalent Input Noise (not integrated) | <200 µV RMS |
Tachometer/Speed Inputs
| Parameter | Value |
|---|---|
| Number of Inputs | 2 per MPC4 card |
| Input Types | Proximity probes, magnetic pickups, TTL signals |
| Frequency Range | 0.1 Hz to 25 kHz |
| Input Voltage | TTL: 0 to 5 V Proximity: -24 to +24 V |
| Speed Accuracy | ±0.05% of reading |
Output Connections
Connect external devices such as recorders, alarms, or control systems to the output terminals on the IOC4T card.
Communication Connections
For remote configuration and monitoring, connect the VM600 rack to a computer or network using the appropriate communication interface (RS-232, Ethernet, etc.).
Configuration and Operation
Configuration Methods
The MPC4 card can be configured using the following methods:
The primary method of configuration is through the VM600 MPSx software, which provides a comprehensive interface for setting up all parameters, alarms, and monitoring functions.
Basic operational parameters can be monitored using the front panel LEDs, which indicate status and alarm conditions.
For remote configuration, the card can be accessed through the VM600 rack’s communication interfaces using appropriate software.
Set Alarm Parameters
| LED Color | Status | Meaning |
|---|---|---|
| Green | Steady | Normal operation, no alarms |
| Yellow | Steady | Alarm condition (warning level) |
| Red | Steady | Danger condition (shutdown level) |
| Red | Flashing | System error or malfunction |
| Off | – | No power or card not properly seated |